LH2H
Cautions for use
1. Non-voltage input type
For both panel mounting and PC
board mounting types
1) Never apply voltage to the non-voltage
input type. This will damage the internal
elements.
2) Since the current ?ow is very small
3) When wiring, try to keep all the input
lines to the start and reset inputs as short
as possible and avoid running them
together with high voltage and power
transmission lines or in a power conduit.
Also, malfunctions might occur if the
?oating capacitance of these wires
5. Backlight luminance
To prevent varying luminance among
backlights when using multiple Backlight
types, please use the same backlight
power supply.
from the start input and reset input
exceeds 500 pF (10 m 32.808 ft. for
24V DC
2
5
2
5
2
6
2
6
24V DC
terminals ( 1 and 3 on the panel
mounting type and terminals e to t and
S to F on the PC board mounting type)
please use relays and switches with high
contact reliability. When inputting with an
open collector of a transistor, use a
transistor for small signals in which ICBO
is 1 μA or less and always input with no
voltage.
3) When wiring, try to keep all the input
lines to the start and reset inputs as short
as possible and avoid running them
together with high voltage and power
transmission lines or in a power conduit.
Also, malfunctions might occur if the
?oating capacitance of these wires
exceeds 500 pF (10 m 32.808 ft. for
parallel wires of 2 mm 2 ). In particular,
when using shielded wiring, be careful of
the capacitance between wires.
PC board mounting type
1) For external power supply use
manganese dioxide or lithium batteries
(CR type: 3V).
2) Always reset after external power is
applied and con?rm that the display
reads “0”.
3) Make the wiring from the battery to the
hour meter unit as short as absolutely
possible. Also, be careful of polarity.
4) Calculate battery life with the following
formula.
t = A/I
t: battery life [h]
I: LH2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached [mAh]
5) Hand solder to the lead terminal. Do
not dip solder. With the tip of the
soldering iron at 300°C 572°F perform
soldering within 3 seconds (for 30 to 60
W soldering iron).
2. Voltage input type
1) Be aware that applying more than 30 V
DC to start input terminals 1 and 2 , and
reset input terminals 3 and 4 will cause
parallel wires of 2 mm 2 ).
3. Free voltage input type
1) Use start input terminals 1 and 2 for
free voltage input and reset terminals 3
and 4 for non-voltage input.
2) Be aware that the application of
voltage that exceeds the voltage range of
the H level to the start input terminal, and
the application of voltage to the reset
input terminal, can cause damage to the
internal elements.
3) Since the current ?ow is very small
from reset input terminal 3 , please use
relays and switches with high contact
reliability.
4) When inputting a reset with an open
collector of a transistor, use a transistor
for small signals in which ICBO is 1 μA or
less and always input with no voltage.
5) To reset externally, short reset input
terminals 3 and 4 on the rear.
6) Input uses a high impedance circuit;
therefore, erroneous operation may occur
if the in?uence of induction voltage is
present. If you plan to use wiring for the
input signal that is 10 m or longer (wire
capacitance 120 pF/m at normal
temperature), we recommend the use of
a CR ?lter or the connection of a bleeder
resistor.
4. How to reset multiple panel
mounting type counters all at once
(input is the same for count)
Non-voltage input type
D D D
Tr
3 4 3 4 3 4 or
Notes) 1. Use the following as a guide for choosing
transistors used for input (Tr).
Leakage current < 1 μA
2. Use as small a diode (D) as possible in the
forward voltage so that the voltage between
terminals 3 and 4 during reset input meets
the standard value (0.5 V).
( At IF = 20 μA, forward voltage 0.1 and
higher.)
Voltage input type
Green Red
6. Acquisition of CE marking
Please abide by the conditions below
when using in applications that comply
with EN 61010-1/IEC 61010-1
1) Ambient conditions
? Overvoltage category II, pollution level 2
? Indoor use
? Acceptable temperature and humidity
range: –10 to +55°C, 35 to 85%RH (with
no condensation at 20°C)
? Under 2000 m elevation
2) Use the main unit in a location that
matches the following conditions.
? There is minimal dust and no corrosive
gas.
? There is no combustible or explosive
gas.
? There is no mechanical vibration or
impacts.
? There is no exposure to direct sunlight.
? Located away from large-volume
electromagnetic switches and power
lines with large electrical currents.
3) Connect a breaker that conforms to
EN60947-1 or EN60947-3 to the voltage
input section.
4) Applied voltage should be protected
with an overcurrent protection device
(example: T 1A, 250 V AC time lag fuse)
that conforms to the EN/IEC standards.
(Free voltage input type)
7. Terminal connection
Tighten the terminal screws with a torque
of 0.8 N·cm or less.
damage to the internal elements.
2) For external resetting use H level
3 4
3 4
3 4
R
Tr
+V
or
3 4
+V
(application of 4.5 to 30 V DC) between
reset terminals 3 and 4 of the rear
terminals. In this case, connect + to
terminal 3 and – to terminal 4 . This is
Note) Make sure that H (reset ON) level is at least 4.5
V.
the valid polarity; therefore, the hour
meter will not work if reversed.
All Rights Reserved ? C OPYRIGHT Matsushita Electric Works, Ltd.
相关PDF资料
LKP5660-7R EURO-CASSETTE 250W 2X 24V
LOK4001-2RLD DIN RAIL 26W 5.1V
LP0125CCKW01A SWITCH PUSHBUTTON DPDT 3A 125V
LP0125CMKW015FB SWITCH PUSHBUTTON DPDT 3A 125V
LPI50XXX1K247XX SWITCH PUSHBUTTON DPST 5A 12V
LRA32H2BBALN SWITCH ROCKER DPST 10A 125V
LRA511-CR-1/012V SWITCH ROCKER SPST 10A 30V
LRGSEK610-RS-B-A/125N SW ROCKER DPST 20A SLD
相关代理商/技术参数
LH2H-F-HMK-DL-B 制造商:PANASONIC ELECTRIC WORKS - ACSD 功能描述:TIME COUNTER 10KDAY VDC W/BCKLGT 制造商:PANASONIC INDUSTRIAL AUTOMATION SALES 功能描述:TIME COUNTER 10KDAY VDC W/BCKLGT 制造商:Panasonic Electric Works 功能描述:Din Half Size Hour Meter With 1. 8.7 Mm Character Height
LH2H-F-HMK-FV 功能描述:控制器 TIME COUNTER 10KDAY VAC/DC INPUT RoHS:否 制造商:Omron Industrial 模拟/数字:Digital 类型:Digital Temperature Controller 显示器类型:11-Segment, 4 Digit 电源电压:100 VAC to 240 VAC 安装: 控制方法: 大小:48 mm x 48 mm
LH2HP-FEW-HMKB-DC24V 功能描述:DIGITAL HOUR METER 制造商:panasonic industrial automation sales 系列:LH2H 零件状态:在售 类型:- 工作模式:- 计数速率:- 时间格式:- 每行字符数:- 显示类型:- 显示字符 - ?高度:- 输入类型:- 输出类型:- 电压 - 电源:- 复位:- 面板开口尺寸:- 安装类型:- 端子类型:- 侵入防护:- 工作温度:- 重量:- 标准包装:1
LH2RR1S056 制造商:OMRON AUTOMATION AND SAFETY 功能描述:FIXED MNT 2D/LINEAR BC READER 制造商:Omron Corporation 功能描述:
LH2RR1S-056 制造商:OMRON AUTOMATION AND SAFETY 功能描述:FIXED MNT 2D/LINEAR BC READER 制造商:OMRON INDUSTRIAL AUTOMATION 功能描述:Fixed mnt.2D/Linear BC reader
LH3 制造商:CML Innovative Technologies 功能描述:LAMP HOLDER WEDGE BASE T1.1/2
LH3 制造商:SLI VCH 功能描述:LAMPHOLDER WEDGE BASE T1.1/2
LH3020-2 制造商:Power-One 功能描述:AC/DC PS TRIPLE-OUT 5.1V/12V/12V 5A/0.7A/0.7A 70W 11PIN - Bulk